HK(L)YE IE5 Multistage Pump

The HK(L)YE IE5 multistage pump combines a rare-earth permanent magnet motor with an integrated VFD to achieve 95% efficiency and 5–20% additional energy savings over conventional VFD pumps, operating across a 30–150 Hz range with near-unity power factor. All-304 stainless steel construction and 3–5 dB(A) quieter operation make it the definitive choice for green buildings and LEED/BREEAM certification.

Share Product :

The HK(L)YE IE5 multistage pump sets a new benchmark for ultra-high-efficiency water pumping systems. Featuring a rare-earth permanent magnet (PM) synchronous motor and an integrated variable-frequency drive, it achieves motor efficiencies of up to 95%, exceeding the capabilities of conventional IE3-class induction motor pumps. With a broad operating range of 30–150 Hz, the HK(L)YE delivers an additional 5–20% reduction in energy consumption compared with standard VFD-controlled induction pumps. Designed for sustainable buildings and energy-conscious facilities, it is the preferred choice for LEED-certified developments, net-zero energy projects, and applications focused on reducing total lifecycle costs.

With a near-unity power factor of 0.95–0.99 and noise levels 3–5 dB(A) below equivalent induction-motor pumps, the HK(L)YE is also the quietest and most grid-friendly multistage pump in its class.

Permanent Magnet Motor: Why It Matters

Traditional induction motors lose energy in two ways: stator copper loss (current flowing through stator windings) and rotor copper loss (induced current in the rotor bars). The PM motor eliminates rotor copper loss entirely because its rotor uses embedded rare-earth magnets to generate the magnetic field — no induced current is needed.

This fundamental advantage translates into measurable performance gains across every operating point:

IE3 Induction vs. IE5 PM Motor Comparison

ParameterIE3 Induction (HK(L)E)IE5 Permanent Magnet (HK(L)YE)
Rated-load efficiency87 – 89%94 – 96%
50% load efficiency78 – 82%91 – 93%
Rotor copper lossPresent (5–8% of input)Zero
Power factor0.82 – 0.870.95 – 0.99
Noise level at 1 m65 – 72 dB(A)60 – 68 dB(A)
Frequency range30 – 60 Hz30 – 150 Hz
Speed regulation accuracy±1%±0.1%
Energy classIE3IE5 (Ultra Premium)

The broader 30–150 Hz operating range also means the HK(L)YE can deliver both very low flows at high pressure (high frequency, throttled) and very high flows at moderate pressure (low frequency) from a single pump unit — reducing the need for multiple parallel pumps.

Ultra-Quiet Operation

The PM motor’s absence of rotor bars and reduced electromagnetic excitation cut acoustic emissions by 3–5 dB(A) compared with an equivalent induction motor at the same speed. This seemingly small difference is perceptible to the human ear and can be decisive in:

  • Hotel guest-room corridors where mechanical-room noise transmits through walls
  • Hospital wards where nighttime noise limits apply
  • Luxury residential towers where pump rooms share a floor plate with occupied spaces
  • Office buildings where low ambient noise is a LEED IEQ credit criterion

Green Building and Sustainability Benefits

The HK(L)YE is purpose-built for projects targeting green building certifications:

  • LEED v4/v4.1 EA Optimize Energy Performance — The ultra-high motor efficiency directly contributes to energy-performance points.
  • Net-Zero Energy Buildings — Minimizing pump energy consumption reduces the size and cost of renewable energy systems needed to offset annual energy use.
  • China GB 19762 Pump Efficiency Standard — Exceeds the highest efficiency grade, qualifying for government energy-saving procurement lists.
  • Lowest Life-Cycle Cost — Over a 15-year pump lifetime, the cumulative energy savings from an IE5 PM motor can exceed 2–3 times the pump’s purchase price.

Technical Specifications

ParameterSpecification
Flow rate (Q)0.4 – 85 m³/h
Head (H)Up to 245 m
Working pressureUp to 2.5 MPa (25 bar)
Medium temperature-15 °C to +120 °C
Motor typePermanent magnet synchronous
Motor efficiency classIE5 (Ultra Premium)
Rated efficiency94 – 96%
Frequency range30 – 150 Hz
Power factor0.95 – 0.99
VoltageThree-phase 380 V, 50 Hz
Control modeClosed-loop PID constant-pressure
Hydraulic materialSUS304 stainless steel
Mechanical sealSilicon carbide / graphite
Connection typesF, N, T, K, L
ProtectionIP55, built-in VFD + PM protections
Noise at 1 m60 – 68 dB(A)

Applications

The HK(L)YE IE5 multistage pump delivers its greatest value in high-runtime, efficiency-sensitive installations:

  • LEED / Green Building Projects — Achieve higher energy-performance scores and qualify for green-building tax incentives.
  • Net-Zero Energy Buildings — Minimize the energy footprint of water supply systems to reduce on-site renewable energy requirements.
  • Noise-Sensitive Hotels & Hospitals — Ultra-quiet operation meets stringent acoustic specifications without additional sound attenuation.
  • High-Runtime Systems — In applications operating 16–24 hours per day, the IE5 efficiency advantage compounds into enormous savings over the pump’s 15+ year service life.
  • District Heating & Cooling — High part-load efficiency ensures minimal waste during seasonal demand variations.

Frequently Asked Questions

What does IE5 efficiency mean?

IE5 is the highest motor energy-efficiency class defined by IEC 60034-30-1, often labeled “Ultra Premium Efficiency.” It requires motor losses to be 20–30% lower than IE4 and 40–50% lower than IE3. The HK(L)YE’s permanent magnet motor achieves this through the elimination of rotor copper losses and optimized electromagnetic design. In practical terms, an IE5 motor converts a significantly larger fraction of input electrical energy into useful mechanical output, reducing both electricity bills and carbon emissions.

How much more efficient is it compared with a standard VFD pump?

At rated (full) load, the HK(L)YE is approximately 6–8 percentage points more efficient than an IE3 induction VFD pump. At part load (50% flow), the advantage widens to 10–14 percentage points because the PM motor maintains high efficiency across the entire speed range while induction motor efficiency drops steeply at lower frequencies. In real-world building water-supply applications, this translates to 5–20% additional energy savings beyond what a conventional VFD pump already provides.

Is the permanent magnet motor reliable over the long term?

Yes. The rare-earth magnets in the HK(L)YE rotor are rated for thermal stability up to 180 °C and experience negligible magnetic flux degradation under normal operating conditions. Demagnetization risk only arises if the motor is subjected to severe over-temperature events far beyond the controller’s thermal protection thresholds — scenarios the built-in VFD actively prevents. With an expected service life of 15+ years, the PM motor’s reliability is comparable to or better than standard induction motors, especially since the rotor has no windings, bars, or bearings to fail.

Get In Touch

We will answer your email shortly!